Bobcat Brushcat 54 in (35cc): specs & which machines can run it
Brush Cutter rated for 9–12.5 GPM. Good fit on 0 of the 64 loaders we track.
Specs
- Type
- Brush Cutters
- Flow class
- standard
- Min flow
- 9 GPM
- Max flow
- 12.5 GPM
- Min pressure
- not published
- Max pressure
- not published
- Min HP
- not published
- Max HP
- not published
- Width
- 54 in
- Weight
- 1042 lb
Source: https://www.bobcatcce.com/assets/PDFs/2025-Bobcat-Catalog-compressed.pdf (official doc (2025 Bobcat attachment catalog) hosted by dealer)
Placeholder · affiliate link
Affiliate / “get a quote” link for Bobcat Brushcat 54 in (35cc) goes here. No affiliate program is connected yet.
Placeholder · featured partner slot
Featured maker / dealer slot — Bobcat dealers. Reserved for a future paid placement. No partner has been signed. This box is intentionally empty.
Verify with your dealer. Results come from published specs and our matching rules. They are not a guarantee. Coupler type, case-drain line, electrical connectors, auxiliary options, relief settings and model year all matter. Confirm with the dealer and the attachment maker before you buy or run anything.
Machines that can run the Bobcat Brushcat 54 in (35cc)
0 good fit3 marginal61 won't run
- MarginalASV RT-50 (standard flow)13.3 GPM is above the 12.5 GPM maximum (up to 15%) - needs flow limiting; risk of heat/overspeed.
- MarginalBobcat S70 (standard flow)8.9 GPM is up to 10% below the 9 GPM minimum - expect reduced speed/power. Head weighs 1042 lb, more than the 760 lb rated operating capacity.
- Marginal
- Won't runASV RT-135 (standard flow)20 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runASV RT-135 Forestry (standard flow)20 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runASV RT-65 (standard flow)21.4 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runASV RT-75 (standard flow)22.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runASV VT-100 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runASV VT-75 (standard flow)21.4 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runASV VT-80 (standard flow)24.7 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S450 (standard flow)16.7 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S590 (standard flow)17.1 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S64-2 (standard flow)17.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S650 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S66-2 (standard flow)17.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S76-2 (standard flow)23.3 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S770 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat S86-2 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T450 (standard flow)16.7 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T595 (standard flow)17.1 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T64-2 (standard flow)17.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T650 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T66-2 (standard flow)17.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T76-2 (standard flow)23.3 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T770 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runBobcat T86-2 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR270B (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR310B (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TR340B (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV370B (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV450B (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCASE TV620B (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 239D3 (standard flow)18 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 249D3 (standard flow)18 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 259D3 (standard flow)20 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 279D3 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 289D3 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 299D3 (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runCat 299D3 XE (standard flow)23 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 317G (standard flow)17 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 325G (standard flow)21 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 331G (standard flow)23.5 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runJohn Deere 333G (standard flow)25 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runKubota SVL65-2 (standard flow)17.4 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runKubota SVL75-3 (standard flow)19.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runKubota SVL97-2 (standard flow)23.1 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C327 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C332 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C334 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C337 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C345 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland C362 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L316 (standard flow)18.4 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L318 (standard flow)20.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L320 (standard flow)20.6 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L321 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L328 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runNew Holland L334 (standard flow)24.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL10V2 (standard flow)18.8 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL11R3 (standard flow)23.1 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL12R2 (standard flow)23.3 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL12V2 (standard flow)23.2 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL6R (standard flow)17.7 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.
- Won't runTakeuchi TL8R2 (standard flow)20 GPM is far above the 12.5 GPM maximum - wrong motor size for this circuit.